Just like its cousin with the Hex Connection, this implant is particularly suitable for use with cancellous upper jaw bones, due to its special micro thread, but it also offers a quick and safe solution in hard bone. The conical inner connector Cone Connection integrates the Platform Switching approach convincingly within the overall implant concept, and is aimed at users who do not want to go without the features of an inner cone in their daily work.

Connection: Cone

Accessories

Plastic sleeve POM, for Multi Unit
Acrylic sleeve made of POM (polyoxymethylene) for the Multi Unit System, can be burned out.
Details
PreFace Abutment (for Cone Connection)
Variante: 5,3 mm / D = 11,5 mm
Our PreFace®-Abutments facilitate the use of PreFace®-Abutment Holders by Medentika. The PreFace®-Abutments are available in the diameters 11.5 mm and 16 mm and with the connection geometries Hex Connection and Cone Connection. This offers the user the necessary variability. The abutments are made of titanium grade 5 which makes them easy and safe to handle. Titanium grade 5 is also highly biocompatible.Your benefits:With PreFace Abutments® you will achieve a superior added value by flexibility – Use our PreFace®-Abutments together with the PreFace®-Abutment Holders by Medentika. saving time – Two different blank diameters guarantee significantly shorter working times in production. exact definition of the zero position – The uniform length despite the different diameters lets you define the zero position almost exactly. variability – The two different diameters 11.5 mm and 16 mm facilitate flexible work.  precision – The preset production processes as well as the standard production processes provide for even more precise results. Material: Titanium grade 5  
Details
Locator matrix set (3 parts),
In the smallest version, the Locator® has a total height of 3.3 mm with a retention housing and nylon insert. ,This makes the Locator® System also suitable in circumstances where vertical space is limited.
Details
Adhesive base, 3.3 mm, (for Cone Connection)
Variante: 3,3 mm
Using this titanium base (titanium grade 5), you can glue both individual crowns and bridge constructions made from ZrO2. For this, we recommend Sebond Implant and Alphalink Implant.
Details
Adhesive base 3.3 mm, CEREC, (for Cone Connection)
Variante: Klebebasis 3,3 mm, CEREC
Produce individual CAD/CAM designed and milled implant abutments and individual tooth restorations on IMPLA implants with the IMPLA adhesive base CAD/CAM CEREC®. Based upon the Sirona CEREC® System.
Details
Locator impression post,
For transferring the situation in the mouth to the impression.
Details
Insertion aid long machine-driven 2.0 mm, (for Cone Connection 3.3/4.2 mm)
Variante: Eindrehhilfe lang, masch. 2,0 mm
Screwdriver with connection geometry 2 mm for all Cone Connection implants. For making fine adjustments to the implant in the bone after the insertion post which comes with the implant packaging has already been removed (Cone Connection series, diameter 3.3 mm and 4.2 mm). The screwdriver can be used with a contra-angle, manually with the adapter art. no. 636077 or with the torque ratchet.
Details
Vertical screw POM,
This vertical screw made of POM facilitates an optimal adhesion at the connection between adhesive base and CAD/CAM element. The perfect fit of the plastic screw reliably prevents adhesive residue from entering the screw channel.
Details
activator / deactivator,
Using this wrench, the gold inner matrix can be compressed (activated) or expanded to match the position of the prosthesis.
Details
Locator instrument, three-part,
Screwed stainless steel tip for removing retention inserts, mid section for repositioning the retention inserts, and gold coloured insertion aid for final screwing of the Locator®.
Details
torque ratchet,
A socket for the different tools, such as screwdrivers and tighteners, is located on the head of the ratchet. It restricts the torque previously set on the tensioning screw - between 0 and 30Ncm - by slipping off the ratchet head. This torque limit can be disabled by twisting the head, in order to tighten implants into the perfect position, for example. The direction of rotation is marked on the ratchet head. We recommend taking the ratchet apart for purposes of cleaning and sterilisation.
Details
bar screw,
Connection screw for constructions on cone adapters, ensures permanent fixing of the supra construction on the cone adapter, as well as the bar and the screwed bridge construction, also with the SAE technique. ,
Details
Acrylic abutment 4.2 mm, Conical Hybrid Connection,
Variante: 4,2 mm
Model and cast individual abutments with this burn out material which leaves virtually no trace. This acrylic abutment combines well with the modelling waxes and acrylics used in most dental labs. This gives clean casting results and a good fit for all your technical dental work. Thanks to precisely manufactured hexagonal connection of the acrylic structure, you have a high degree of rotation protection.  Indications: Bar restorations Individual crowns Bridges Temporary abutment
Details
Insertion aid 2.5 mm for Cone Connection 5.3 mm
Variante: kurz
Ratchet tool to change the insertion depth or the hex position of IMPLA Cone Connection implants after removal of the insertion post (part of the packaging).The tip of this tool fits precisely into the implant geometry. It can be used manually or with a torque ratchet,.
Details
Locator plugin, extended range, 4 pcs./green,
Nylon matrix for insertion into the Locator matrix housing. Without centric retention, 20° divergence compensation, shearing force 1.360-1.800 g.
Details
Gingiva sleeve PEEK, (for Multi Unit)
PEEK gingiva sleeve for the Multi Unit System, can be adjusted individually.
Details
Locator plugin, extra light retention 4 pcs./blue,
Nylon matrix for insertion into the Locator matrix housing. With centric retention, 10° divergence compensation, shearing force 680 g.
Details
torque wrench 4 Ncm,
Using this torque wrench the inner matrix is screwed into the matrix housing and set onto the patrix. Inner assembly matrices with blue acrylic inserts should not be used as permanent inner matrices in prostheses, they are intended exclusively for use in the dental laboratory.
Details
Parallelization aid for implants,
This parallelling device is used to check the pilot drilling and to check that the drill holes are parallel. It is also suitable to check the DVT (drilling depth).
Details
Depth gauge 3.3mm brown,
Variante: 3,3 mm
For checking the plant implant insertion depth after use of the pilot drill.
Details
Enlargement drill
Variante: 2,5 mm
Use this extension drill without internal cooling for the preparation of implant sites for IMPLA implant lines Dual Surface and Micro Retention. The suitable drill diameter is selected from the drill protocol depending on the implant diameter and the drilling depth.The depth inside the bone is controlled during the drilling process with help of the depth marks on the drill. The drills with the diameters 3.15 mm and 4.25 mm are available in a short version for use in the molar region.
Details
Conical connector 3.3 mm individ. millable, (for Cone Connection)
Variante: 3,3 mm
This grade 5 titanium abutment is adapted individually in the lab where angulation of greater than 15° is required with the IMPLA Cone Connection system.
Details
parallel positioning aid,
For straight placement of model axes in master models.
Details
open-end pick-up,
This open ended wrench is needed for transfer of the implant into the IPK wrench, and insertion via the drilling template. The open ended wrench can also be used for non-contact removal of the implant from the packing, even where the opening of the patient’s mouth is limited (Pick Up technique).
Details
inner matrix yellow/light,
Variante: Gelb / Schwach
If the inner matrix is exchanged during a recall, it can be replaced in seconds by a completely new inner matrix, using a specially made torque wrench. Three color-coded inner matrices with standardized shearing force are available. With existing prostheses where the acrylic inner matrix appears too weak, this can be exchanged for the precious metal inner matrix very easily,without having to change the retention cap!
Details
Pilot drill 2.0 mm,
Surgical pilot drill without internal cooling for different drill settings during the preparation of the implant site for the IMPLA implant lines Cylindrical, Dual Surface and Micro Retention (according to the drill protocol, limited use for Mini and Interim).
Details
Countersink cutter 3.3 mm,
Variante: Bettfräser 3,3 mm
Site drill without internal cooling for shaping the implant silhouette in the bone of IMPLA implants Micro Retention or Dual Surface.
Details
Scan abutment for Multi Unit,
This bowling pin shaped PEEK abutment is excellently suited for digital measuring with optical scanners or laser scanners. The Best Fit-function of the design software is precisely supported by an additional levelled surface.Preparing the scan abutment with scan spray is not necessary, as it is optimally scanned because of its dull whitish color.
Details
Transfer cap for Mini implant conetop,
By attaching the acrylic cap this locks on cleanly to the impression post or directly onto the connection on the Mini-conetop implant. After a successful impression, the transfer cap remains in the impression and helps fix the corresponding laboratory analogue. The acrylic transfer cap is not suitable for use more than once!
Details
Scanabutment 3,3 mm Conical Hybrid Connection
Variante: 3,3 mm
Abutment for digital scanning of model situations on the master model. For IMPLA Cone Connection. This PEEK abutment is especially well-suited for digital measurement with optical scanners or laser scanners, due to its bowling pin shape. The Best Fit-Function of the construction software is supported by an additional flattened surface. The scan abutment does not need to be prepared with scan spray due to its whitish matt color. Your benefits: Extraordinary digital measurement due to the bowling pin shape No preparation with scan spray necessary Easy recognition of the size with help of laser markings Made in Germany
Details
Conical connector 5.3 mm Cone Connection
Variante: 15°/1 mm
This abutment made of titanium grade 5 with its conical implant connection geometry and its tailor-made emergence profile was specially developed for the IMPLA Cone Connection line. Supra constructions can be either cemented or adhesion-fixed.Available with gingiva heights of 1 mm, 3 mm or 5 mm and with angles of 0°, 15° or 20°.
Details
PreFace Abutment (for Cone Connection)
Variante: 5,3 mm / D = 16 mm
Our PreFace®-Abutments facilitate the use of PreFace®-Abutment Holders by Medentika. The PreFace®-Abutments are available in the diameters 11.5 mm and 16 mm and with the connection geometries Hex Connection and Cone Connection. This offers the user the necessary variability. The abutments are made of titanium grade 5 which makes them easy and safe to handle. Titanium grade 5 is also highly biocompatible.Your benefits:With PreFace Abutments® you will achieve a superior added value by flexibility – Use our PreFace®-Abutments together with the PreFace®-Abutment Holders by Medentika. saving time – Two different blank diameters guarantee significantly shorter working times in production. exact definition of the zero position – The uniform length despite the different diameters lets you define the zero position almost exactly. variability – The two different diameters 11.5 mm and 16 mm facilitate flexible work.  precision – The preset production processes as well as the standard production processes provide for even more precise results. Material: Titanium grade 5  
Details
Conical connector 3.3 mm Cone Connection
Variante: 15° / 1 mm
This abutment made of titanium grade 5 with conical implant connection geometry and ready-made emergence profile is an accessory for the implants of the IMPLA Cone Connection series. Supra constructions can be fixed with cement or adhesive. Available for gingiva heights of 1 mm or 3 mm and for angles of 0° or 15°.
Details
Gingiva former conical 4.2/3 mm, (for Cone Connection), sterile
Variante: 4,2 mm / 3 mm
Titanium grade 5 healing component with processed emergence profile for implants in the conical connection range. With this, you can displace the gingiva without any pain, in order to prepare an aesthetically appropriate design of the final prosthesis. The formers can be fitted over the crestal 1.2 mm hexagonal connector both manually and mechanically. ,
Details
Depth stop set,
Variante: Tiefenstopp Set
For an even higher level of safety in implantologyAccessory for IMPLA surgical drills (with suitable drill coil), mechanical depth stop in the jaw bone. Simply attach the depth stop to the drill. Your benefits: Easy handling Safe friction fit Color coding for easily matching the depth stop to the according surgical drill The depth stop is available in three different diameters: narrow (brown), medium (red) and wide (blue). By means of the color coding and the print with the drilling depth on the depth stop, it can be matched easily to the according surgical drill. The depth stops are available in each implant length. The drills can be used with or without the depth stop. Set contains: 5x depth stop narrow / brown: je 1x 6.5 mm, 8.0 mm, 9.5 mm, 11.5 mm, 13.0 mm 5x depth stop medium / red: je 1x 6.5 mm, 8.0 mm, 9.5 mm, 11.5 mm, 13.0 mm 5x depth stop wide / blue: je 1x 6.5 mm, 8.0 mm, 9.5 mm, 11.5 mm, 13.0 mm
Details
Locator plugin, extended range, light retention, 4 pcs./red
Nylon matrix for insertion into the Locator matrix housing. With centric retention, 20° divergence compensation, shearing force 220-680 g.
Details
Enlargement drill short 2.5 mm,
Variante: Erweiterungsbohrer kurz 2,5 mm
Extension drill, short, without internal cooling, diameters 2.5 mm, 3.15 mm and 4.25 mm for all IMPLA Micro Retention implant lines.Depth stops are available for all pilot drills and extension drill. These depth stops give the user security and control, even in difficult anatomical situations.
Details
Insertion aid 2.0 mm for Cone Connection 3.3/4.2 mm
Variante: lang
Ratchet tool to change the insertion depth or the hex position of IMPLA Cone Connection implants after removal of the insertion post (part of the packaging).The tip of this tool fits precisely into the implant geometry. It can be used manually or with a torque ratchet,.
Details
model axis,
Stainless steel laboratory analogue for production of models.
Details
Conical connector 3.3/0° GH=1, (for Cone Connection)
Variante: 3,3 mm / 1 mm
This abutment made of titanium grade 5 with conical implant connection geometry and ready-made emergence profile is an accessory for the implants of the IMPLA Cone Connection series. Supra constructions can be fixed with cement or adhesive. Available for gingiva heights of 1 mm or 3 mm and for angles of 0° or 15°.
Details
Locator lab implant,
For transferring the impression situation to the master model.
Details
Cortical drill 2.0/3.15 mm,
Variante: Kortikal-Bohrer 2,0 / 3,15 mm
Without internal cooling. Ideally use on D1 and D2 bones. Cortical drill for the extension of 2 mm pilot drillings to 3.15 mm diameter of the next drill setting in the corticalis.
Details
pilot drill 1.8 mm,
The pilot hole created by the pilot drill in the bone guides the tip of the pre-drill which follows, and keeps it from slipping in difficult to reach areas or in unfavorably shaped jaw ridges.
Details
Vertical screw standard, Vertical screw for Impla Direkt GH 1.5 mm
Has a fine thread, which meshes perfectly with the inner thread of the implant, cold welded. This make it practically impossible for the abutment to become loose.
Details
Lab implant 5.3 mm, Cone Connection
Variante: 5,3 mm
Titanium transfer element for accurate replication of implant position together with the impression aid for implants in the conical connection range. Can be used with both the open and the closed impression technique. ,
Details
Fixation screw OT for Multi Unit,
This fixation screw is suited to be used with the forming aid Multi Unit. Due to the knurling at the screw head, this screw is safe and easy to use.
Details
Universal Drilling Guide,
The Universal Drilling Guide is a drilling aid and supports you when inserting the distal implants: Pilot drilling mesial without angulation. Starting from this situation you can align the implants with help of the Universal Drilling Guide in 0°, 20° and 30°. The Universal Drilling Guide is especially well suited for the Multi Unit System.
Details
Conical connector 4.2 mm Cone Connection
Variante: 15°/1 mm
This abutment made of titanium grade 5 with its conical implant connection geometry and its tailor-made emergence profile was specially developed for the IMPLA Cone Connection line. Supra constructions can be either cemented or adhesion-fixed. Available with gingiva heights of 1 mm, 3 mm or 5 mm and with angles of 0°, 15° or 20°.
Details
Locator abutment D = 5.3 mm GH = 5.0, (Cone Connection)
Variante: 5,3 mm / 5 mm
Modern prosthetic solution with the original Zest Locator abutment for the cover denture / full denture fixing technique for full or partial prostheses. The prosthesis keeps its firm hold due to the cylindrical shape of the Locator. The special shape of the retention facilitates a low installation height and a divergence equalisation up to 15°. Also in various sizes of acrylic holding matrices for polymerisation for the Impla conical connection range.
Details
Locator replacement plugin, 4 pcs./clear,
Nylon matrix for insertion into the Locator matrix housing. With centric retention, 10° divergence compensation, shearing force 2.260 g.
Details
Impression post Multi Unit,
An impression aid for impressions of Multi Unit abutments on abutment level. Fix the impression aid on the Multi Unit abutments with help of the fixation screw OL.
Details
adapter ratchet for Locator adapter contra-angle,
Tool for manual unscrewing the Locator abutment in conjunction with 636075 in the torque ratchet.
Details
bone thread cutter 5.3 mm,
Variante: 5,3 mm / universal
Precutting the thread reduces the screw-in torque especially in D1 and D2 bone qualities, to avoid overheating and extreme compression. Use the thread cutter considering the drilling protocol for Micro Retention and Dual Surface implants.
Details
Locator adapter, with contra-angle connector,
Tool for unscrewing the Locator abutment with contra-angle or as an insert in conjunction with 636077 in the torque ratchet.
Details
Metal sleeve (for Multi Unit),
Titanium sleeve made from titanium grade 5 - for friction-free glue fixing on abutments of the Multi Unit System.
Details
Guide key for insertion aid,
Any loosening movement of the implant is prevented by pushing up the outer hexagon on the insertion post when releasing the retaining screw. Furthermore, the insertion post can be loosened if it ever jams.
Details
Locator plugin, light retention, 4 pcs./pink,
Nylon matrix for insertion into the Locator matrix housing. With centric retention, 10° divergence compensation, shearing force 1.360 g.
Details
Module Implantology Tools, assembled, size M
Adapt your IMPLA surgical box according to your individual needs. This compact tray contains all tools necessary for the insertion of an IMPLA Cylindrical or Micro Retention implants. As the tray manages without silicone plugs, it provides for a maximum of hygiene. This tray can be extended optionally.  
Details
vertical screw blue,
Comes with the implant and helps repeated use when making prostheses in the laboratory. Item no 636649 is strongly recommended as the final connection screw.
Details
retention cap, large, for resin curing, for resin curing
Various inner matrices can be screwed into the retention cap using this specially made torque wrench. If the inner matrix gets worn out, they can be replaced easily, without having to change the inner matrix.
Details
retention cap, small, for framework stabilization
Various inner matrices can be screwed into the retention cap using this specially made torque wrench. If the inner matrix gets worn out, they can be replaced easily, without having to change the inner matrix.
Details
Prosthetic screw secondary, (for Multi Unit Abutment)
This screw is used for the fixation of a restoration on Multi Unit Abutments.
Details
Gingivaformer cylindrical 3.3/3 mm, (for Cone Connection), sterile
Variante: 3,3 mm / 3 mm
Cone ConnectionThe cylindrical gingiva former is used to form the gingiva after reopening the implant site. In this process, the implant is extended to a supragingival mucosa level. The cylindrical shape is selected for a graceful emergence profile, especially in cases of very narrow gaps or closely placed implants.
Details
Steribox S, empty, A8/ for 1 module
Variante: für 1 Modul
Sterilization box available in sizes S, M and L, for the sterilization of surgical instruments.Dimensions size S (A8):  Outside dimensions: 90 x 90 x 55 mmInternal dimensions: 65 x 60 x 47 mm Dimensions size M (A6): Outside dimensions: 190 x 110 x 60 mmInternal dimensions: 165 x 92 x 49 mm Dimensions size L (A4): Outside dimensions: 290 x 190 x 60 mmInternal dimensions: 265 x 165 x 49 mm Sterisafe® DURO Sterilization container Sterility barrier and packaging system made from high-performance plastics Suited to almost all steam sterilization procedures under vacuum at temperatures of 121°C (249.8 °F) and 134°C (273.2 °F) as well as to low-temperature sterilization with gas (FORM and EO) and to H2O2/H2O2-plasma (in the following: VH2O2). Only tools which are suited to multiple sterilization and to this sterilization procedure must be sterilized in Sterisafe® DURO. Sterisafe® DURO sterilization container made from high-performance plastics: are translucent are highly shock-resistant (no dents) are >, pH 10 reprocessable can be sterilized with steam, plasma, EO or FO. are maintenance-free (no seal, no erosion), upper and lower part of the container close bacteria-proof according to Pasteur's principle are proven to save downtimes and service cost of your instruments have been well-proven for many years Sterisafe® DURO sterilization container have been designed in accordance with national / international standards and regulations DIN EN 868-1 and -8: 1999 DIN EN ISO 11607-1 and -2: 2006 CE marking in accordance with MDD 93/42 EWG
Details

Cutsomers also bought

FuturaPress LT, powder pink-transparent 1000g,
The acrylic for completing your model cast work. Also suitable for warm summer months, due to a working time of 7-8 minutes. Simple to use, tried and tested for many years. Facilitates filling of three saddles in one process.   Benefits: Excellent physical properties High color stability Low shrinkage
Details
Locator matrix set (3 parts),
In the smallest version, the Locator® has a total height of 3.3 mm with a retention housing and nylon insert. ,This makes the Locator® System also suitable in circumstances where vertical space is limited.
Details
Micro Retention implant 4.2/11.5 mm, (Cone Connection), sterile
Just like its cousin with the Hex Connection, this implant is particularly suitable for use with cancellous upper jaw bones, due to its special micro thread, but it also offers a quick and safe solution in hard bone. The conical inner connector Cone Connection integrates the Platform Switching approach convincingly within the overall implant concept, and is aimed at users who do not want to go without the features of an inner cone in their daily work.
Details
Micro Retention implant 5.3/9.5 mm, sterile, (Hex Connection)
Our Micro-Retention implant is the result of persistent further development of renowned quality. Its specially conceived micro-thread helps it achieve an exceptional degree of primary stability and therefore, safety, even when the bone situation is not favourable, for example in cancellous upper jaw bones, or in the sinus area with reduced residual bone. You also have the option of working with Platform Switching here. The high precision Hex inner connection with rotation protection guarantees a secure connection between implant and abutment. Benefits: Hex connection for rotation-secure connection between implant and abutment Special micro-thread for very high primary stability Optimised thread design for improved primary stability even in soft bones Integrated Platform Switching to improve the soft tissue attachment Micro-constructed, highly pure surface for optimal cell adaptation and safe osseointegration
Details