zebris para-occlusal attachment with lip bow, for Tizian JMA Optic System by zebris

Description

Attachment for fixing the measuring sensors to the lower jaw incl. the lip bow

Product number: 522119
Product information "zebris para-occlusal attachment with lip bow, for Tizian JMA Optic System by zebris"

Attachment for fixing the measuring sensors to the lower jaw incl. the lip bow.

  • surgical steel
  • can be sterilized
  • exclusively suitable to use with  the Tizian JMA Optic System by zebris (not suitable to use with ultrasound based zebris systems!)

Brochures and further information on this product

Cutsomers also bought

zebris para-occlusal attachment with labial arch (deep/cover bite), Tizian JMA Optic System by zebris
Attachment for fixing the measuring sensors to the lower jaw incl. the lip bow. surgical steel can be sterilized exclusively suitable to use with  the Tizian JMA Optic System by zebris (not suitable to use with ultrasound based zebris systems!)
Details
zebris coupling tray, bite fork, type SD
The innovation of the coupling tray in the zebris JMAnalyser+ jaw measuring system (64 bit version) lets you transmit the real movements of your patient to the digital world for the very first time. The data import into the Tizian CAD/CAM system (by Schütz Dental) is carried out with the patented coupling tray which is used as a face bow for the digital environment. Now, you can use the movement data of your patient with the Tizian Creativ RT CAD software. The name ""Real Movement"" describes it all! This tool of the zebris JMAnalyser+ lets you exclusively record the real motion curve and the actual position of your patient's upper jaw. In the past, the virtual articulator could merely show the best possible simulation of the motion curve in relation to your patient's data. A recording of the actual state was not possible. From now on, you can record the real motion pattern of your patient and the actual course of motions in the mouth, and transfer this real data into the digital world via Tizian Creativ RT CAD software. The course of the movements is displayed in the software with help of the real jaw movements of the patient. This procedure is especially well suited for the production of fully anatomic (monolithic) restorations, which can be ground quickly and dynamically. The restoration is produced with an oustanding fit based upon the real situation inside the mouth and helps your patient keep a healthy and comfortable bite.
Details
Tizian Blank NEM fine 98 mm
Tizian Blanks NEM (non-precious metal) are made of beryllium-free and cadmium-free CoCr ceramic alloy according to DIN EN OSP 22674 and EN ISO 9693 for applications with thin cross-sections which are exposed to extreme forces. Examples are removable partial dentures, clasps, thin veneered individual crowns, fixed full arch dentures or bridges with small cross-sections, bars, fixations, implant-supported supraconstructions. Properties: Alloy type: 4Density: 8.8 g/cm³Vickers hardness: 285 HV 10/30CTE- value (25-500 °C): 14,4*10-6 K-1Oxidation without vacuum (Point 4c): 1000 °CMass content of the components (in weight-%)*: Co 63, Cr 29, Mo 6 / Mn x, Nb x, Si x, Fe xTensile strength: 680 MPa0.2 % yield point: 400 MPaElongation at break: 9 %E-module: 250 GPa *X= <, 1%
Details